@us






Share
f
t
youtube

Brass Ball Valves B1001

Nominal diameter DN15-DN100
Media temperature -10°C to 120°C
Pressure Range 25 bars
Permissible medium Water services, heating and air- conditioning plants, compressed air systems
Connection Threaded ISO228 (equivalent to DIN 259 and BS 2779 )
Test Opening/closing test: 10000 times

Brass Check Valves B5007

Nominal diameter DN15-DN100
Media temperature -10 -120°C
Pressure Range 16 bars
Permissible medium Hot and cold water, oils and domestic water service
Connection Threaded ISO228 (equivalent to DIN 259 and BS 2779)
Opening/closing test: 10000 times

Brass Filter B5005

Nominal diameter DN15-DN100
Media temperature -10 -120°C
Pressure Range 16 bars
Permissible medium Hot and cold water, oils and domestic water service
Connection Threaded ISO228 (equivalent to DIN 259 and BS 2779)
Test Opening/closing test: 10000 times

Brass Gate Valves B4030

Nominal diameter DN15-DN100
Media temperature -10 -120°C
Pressure Range 16 bars
Permissible medium Hot and cold water, oils and domestic water service
Connection Threaded ISO228 (equivalent to DIN 259 and BS 2779)
Test Opening/closing test: 10000 times

Butterfly valve Z100

Nominal diameter DN50-DN300
Connection Wafer, Lug
Media temperature EPDM:-10°C to 100°C
NBR:-10°C to 80°C
PTFE:-40 to 200°C
Pressure Range 10/16 bars
Permissible medium EPDM : hot water, cold water HVAC, Irrigation etc. NBR: hydrocarbons, waster water, Sea water fuel, natural gas, oil, grease, compressed air, glycol
Flange Connection PN10/16, ASA150, JIK10K
Design standard EN593
Face to face EN 558-Series 20 and 13/ ISO 5752 series 20/ API 609 table 2
Tightness test of shell According to EN12266-1 Resistance and tightness of the body : test P11 (1,5 x allowable operating pressure)
Tightness of the seat According to EN12266-2 Test P12 rate A (1,1 x allowable Operating pressure)

Butterfly valve Z300

Nominal diameter DN50-DN300
Connection Wafer, Lug
Media temperature EPDM:-10°C to 100°C
NBR:-10°C to 80°C
Pressure Range 10/16/20/25 bars
Permissible medium EPDM : hot water, cold water HVAC, Irrigation etc. NBR: hydrocarbons, waster water, Sea water fuel, natural gas, oil, grease, compressed air, glycol
Flange Connection PN10/16/25, ASA150, JIK10K
Design standard EN593
Face to face EN 558-Series 20 and 13/ ISO 5752 series 20/ API 609 table 2
Tightness test of shell According to EN12266-1 Resistance and tightness of the body : test P11 (1,5 x allowable operating pressure)
Tightness of the seat According to EN12266-2 Test P12 rate A (1,1 x allowable Operating pressure)

Butterfly valve Z301-DN25toDN1200

Nominal diameter Wafer:DN25-DN1200
Lug: DN50-DN1200
Double flange: DN50-DN1200
Connection Wafer
Lug
double flange
Media temperature EPDM:-10°C to 100°C
NBR:-10°C to 80°C
FKM:-5°C to 180°C
Silicon:-40°C to 150°C
Pressure Range 10/16 bars
Permissible medium -EPDM : hot water, cold water HVAC, Irrigation
-NBR: hydrocarbons, waster water, Sea water fuel, natural gas, oil, grease, compressed air, glycol
-FKM:acid,oil, gasoline,glycenne,hydrocarbure,biogaz
-Silicon:high temperature oil, acid,air
Flange Connection PN10/16, ASA150, JIK10K
Design standard EN593
Face to face EN 558-Series 20 and 13/ ISO 5752 series 20/ API 609 table 2
Tightness test of shell According to EN12266-1 Resistance and tightness of the body : test P11 (1,5 x allowable operating pressure)
Tightness of the seat According to EN12266-2 Test P12 rate A (1,1 x allowable Operating pressure)

Check Valves C100

Nominal Diameter DN50 to DN600 (other DN on request)
Media temperature EPDM:-20°C to 150°C
NBR: -10°C to 80°C
Viton:-20°C to 150°C
Max allowable pressure 25 bar
Permissible medium Water, general industry, process, hydrocarbons
Flange Connection PN10/16/25, ASA150/300, JIK10K/16K/
Body GJL250,GJS400,SS316

Check Valves C200

Nominal Diameter DN50-DN100
Media Temperature -20°C to 200°C
Max allowable pressure 40 bars
Permissible medium General industry, corrosive fluids, steam
Flange Connection PN10/16/25, ASA150/300
Body Stainless steel CF8

Check Valves C300

Nominal Diameter DN50 to DN350
Media temperature -10°C to 80°C
Max allowable pressure 16 bars
Permissible medium Clean Water, pre-cleaned sewage water, fire proection, HVAC
Flange Connection PN16
Norms EN 558-1, ISO 5752 and EN 1092-2, ISO 7005-2 flange dimension
Body GJS500-7

Check Valves C300L

Nominal Diameter DN400 to DN600
Media temperature -10°C to 80°C
Max allowable pressure 16 bars
Permissible medium Clean Water, pre-cleaned sewage water, fire proection, HVAC
Flange Connection PN16
Norms EN 558-1, ISO 5752 and EN 1092-2, ISO 7005-2 flange dimension
Body GJS500-7

Check Valves C301

Nominal Diameter DN50 to DN350
Media temperature -10°C to 80°C
Max allowable pressure 25 bars
Permissible medium Clean Water, pre-cleaned sewage water, fire proection, HVAC
Flange Connection PN16
Norms EN 558-1, ISO 5752 and EN 1092-2, ISO 7005-2 flange dimension
Body GJS500-7

Check Valves C301L

Nominal Diameter DN400 to DN600
Media temperature -10°C to 80°C
Max allowable pressure 25 bars
Permissible medium Clean Water, pre-cleaned sewage water, fire proection, HVAC
Flange Connection PN25
Norms EN 558-1, ISO 5752 and EN 1092-2, ISO 7005-2 flange dimension
Body GJS500-7

Check Valves C400

Nominal Diameter DN25 to DN65
Media temperature -10°C to 70°C
Max allowable pressure 16 bars
Permissible medium Waste Water, Viscose liquid
Flange Connection Threaded F/F
Norm EN12050-4
Face to face dimension DIN 3202 F6
Body GJS400

Check Valves C401

Nominal Diameter DN50 to DN400
Media temperature -10°C to 70°C
Max allowable pressure 16 bars till DN150;10 bar above DN150
Permissible medium Waste Water, Viscose liquid
Flange Connection PN16
Norm EN12050-4
Face to Face dimension DIN 3202 F6
Body GJS400

Check Valves C420

Nominal Diameter DN25 to DN50
Media temperature -10°C to 70°C
Max allowable pressure 16 bars
Permissible medium Waste Water, Viscose liquid
Flange Connection Threaded F/F
Norm EN12050-4
Face to face dimension DIN 3202 F6
Body Stainless steel 316

Check Valves C421

Nominal Diameter DN50 to DN200
Media temperature -10°C to 70°C
Max allowable pressure 16 bars till DN100;10 bar above DN100
Permissible medium Waste Water, Viscose liquid
Flange Connection PN16
Norm EN12050-4
Face to face dimension DIN 3202 F6
Face to face dimension DIN 3202 F6
Body Stainless steel316

Check Valves C500

Nominal Diameter DN50 to DN300
Media temperature 0°C to 80°C
Max allowable pressure 16 bars
Permissible medium Clear Water, waste water, water supply, pumping station
Flange Connection PN10/16
Norm EN1092-2
Face to face dimension DIN F6
Body Ductile iron GGG40/50

Y Strainer Y300

Nominal diameter DN32-DN400
Media temperature -20°C to 100°C
Max allowable pressure 16 bars
Permissible medium Water, oil
Flange Connection PN10/PN10
Face to Face dimension DIN 3202 F1
Body GJL500/GJS400

Electric Actuator Bernard AQ range

Torque value 15Nm-500Nm
IP protection 68
Duty rating S4-30% motor duty rating. Up to 120 starts per hour at peak of operation.
Environment temperature : -20°C - 60°C
Voltage 1x85-260V AC 50/60Hz 24V DC
1x115/220/230V AC 50/60Hz
3x380-415V AC 50/60Hz
3x440-480V AC 60Hz
24V DC
Motor Technology DC motors with 2-wire connection
Manual emergency Manual emergency operation via manual hexagonal output 10mm

Electric Actuator ME-MER

Torque value 20Nm-6000Nm
IP protection 67
Duty rating 50%
Environment temperature : 0°C - 80°C
Rotation 90°, 180°, 270°
Voltage AC 24V/110V/220V/380V, DC24V
Application Butterfly valves (till DN700/800)
Ball valves (till DN200/300)
Globe valves
Options: H class Over torque limiter
Anti-condensation heater
Fail safe
Potentiometer: 1K, 3K, 5K
DC 4 to 20mA / DC 1 to5 V position feedback

Gate Valve G100-F4

Nominal diameter DN40-DN600
Media temperature -10°C-80°C
Pressure Range 16 bars
Permissible medium Clear water, Fire protection, irrigation, sewage
Flange Connection PN10/16
Design standard EN1171, EN1074
Face to face dimension EN 558-1, DIN3202 F4/F5, BS5163
Flange drilling EN 1092-2
Tightness test EN 12266-1.EN 12266-1
Epoxy coating 150μm (standard), other thickness on request

Gate Valve G100-F5

Nominal diameter DN40-DN600
Media temperature -10°C-80°C
Pressure Range 16 bars
Permissible medium Clear water, Fire protection, irrigation, sewage
Flange Connection PN10/16
Design standard EN1171, EN1074
Face to face dimension EN 558-1, DIN3202 F4/F5, BS5163
Flange drilling EN 1092-2
Tightness test EN 12266-1.EN 12266-1
Epoxy coating 150μm (standard), other thickness on request

Globe valve-S2000CS

Nominal diameter DN40-DN300
Media temperature -10°C-400°C
Pressure Range 16/325/40 bars
Permissible medium Water, steam, hot oil
Flange Connection PN16/PN25/PN40
Face to face dimension EN 558-1, DIN3202 F4/F5, BS5163
Flange drilling DIN3202-1 F1
Tightness test DIN2533 / DIN2544 / DIN2545
Epoxy coating 150μm (standard), other thickness on request

Control valve GCVD-TLF

Nominal diameter DN15-DN500
Media temperature Water valve(-25~130°C)
Steam valve(2~180°C)
Steam valve(2~220°C)
Steam valve(2~450°C)
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, Glycol, Saturated steam,Overheated steam
Flange Connection PN16/25
Type of valve 2 ways and 3ways
Flanged connection ISO7005-2
Flow characteristic A-AB equal-percentage flow characteristic
B-AB equal-linear flow characteristic
Ratio Less than 0.01% Kvs

Control valve-GCVS-TLT

Nominal diameter DN15-DN50
Media temperature Water valve(-25~130°C)
Steam valve(2~180°C)
Steam valve(2~220°C)
Steam valve(2~450°C)
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, Glycol, Saturated steam,Overheated steam
Flange Connection PN16/25
Type of valve 2 ways and 3ways
Thread connection
Flow characteristic A-AB equal-percentage flow characteristic
B-AB equal-linear flow characteristic
leackage rate Less than 0.01% Kvs

DPCV-TYF

Nominal diameter DN65-DN250
Media temperature -10°C-120°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, Glycol
Connection Flanged connection ISO7005-2
DP setting range 20~80kPa or 40~160kPa
Max. working DP △Pv≤350kPa

DPCV-TYL

Nominal diameter DN15-DN50
Media temperature -10°C-120°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, Glycol
Connection Threaded ISO7-1
DP setting range 5~30kPa or 25~70kPa
Max. working DP △Pv≤250kPa

Double regulating valves-OSF

Nominal diameter DN40-DN500
Media temperature -10°C-150°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, Glycol
Flange Connection PN16/25
Flange standard ISO7005-2

Double regulating valves-OST

Nominal diameter DN15-DN50
Media temperature -10°C-150°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, Glycol
Connection Threaded ISO7-1

Hydraulic Balancing Debugging Instrument-HDB_TPS-2

Max Permissible Pressure 1000kPa
DP Measurement Range up to 1000kPa
Pressure Range 3~1000kPa
Medium Temperature -20~120°C
Measurement Deviation DP Sensor < 0.5%
Flow: DP Deviation + Valve Deviation
Battery Capacity 3000mA
Operating Time >20h
Charge Time 6h
Protection Level IP64
Ambient Temperature Operating and Charging: 0~40°C
Storage Status: -20~60°C
Ambient Humidity max 90%RH
Charger Output Voltage: 12.6V DC
Output Current: 500mA
Applicable System Android
Dimension L*W*H = 470*355*150mm
Electric actuator spec G:
Electric actuator spec H:

PICV-TDT for FCU

Nominal diameter DN15-DN25
Media temperature -10°C-120°C
Max allowable pressure 16, 25 bars
Permissible medium Chilled/hot water,glycol under 50%
Connection F/F threaded connection ISO7-1
Flow Characteristic Linear flow characteristic
Leakage acc. to standard IEC 534 Less than 0.02% of KVS
Voltage 220VAC 50/60Hz
Power consumption ≥2W
Effective troque 100N
Effective stroke ≥4mm
Operating environment Temperature -10~60°C
Connection thread M30*1.5
Protection level IP54
Cable 2*0.75mm 2

PICV-TPF for AHU

Nominal diameter DN50-DN250
Media temperature -10°C-120°C
Max allowable pressure 16, 25 bars
Permissible medium Chilled/hot water,glycol under 50%
Connection Flanged connection ISO7005-2
Flow Characteristic Equal-percentage and linear
Leakage acc. to standard IEC 534 Less than 0.02% of KVS
Voltage 24VAC± 15%,24VDC+ 15% 110~230VAC
Electric actuator spec A: RS485 Remote Control
Electric actuator spec B: NFC (Near Field Communication),The actuator has NFC function which can not only control opening and closing of valve by mobile NFC client, but also set a number of parameters. NFC function can still read actuator parameter even if the actuator is powered off on site.
Electric actuator spec C: The actuator has the self-stroking function.It can automatcially measure the valve stroke.
Electric actuator spec D: The high/low speed can be switched through DIP switch. 500/1000/3000N: high speed 1s/mm, middle speed 2s/mm; 5000N: high speed 2s/mm, middle speed 4s/mm.
Electric actuator spec E: The actuator has the mechanical manual function and manual priority function, that is, when insert the wrench, the actuator will be automatically powered off which is safe and convinent.
Electric actuator spec F: The actuator has local control function which can control the opening and closing of valve by the button on the plate.
Electric actuator spec G: There are LED indicating lights on the actuator cover which is convenient to observe the actuator running status.
Electric actuator spec H: IP54

PICV-TPL for AHU

Nominal diameter DN25-DN50
Media temperature -10°C-120°C
Max allowable pressure 16, 25 bars
Permissible medium Chilled/hot water,glycol under 50%
Connection F/F Threaded ISO7-1
Flow Characteristic Equal-percentage flow characteristic
Leakage acc. to standard IEC 534 Less than 0.02% of KVS
Voltage 24VAC± 15%,24VDC+ 15% 110~230VAC
Electric actuator spec A: RS485 Remote Control
Electric actuator spec B: NFC (Near Field Communication),The actuator has NFC function which can not only control opening and closing of valve by mobile NFC client, but also set a number of parameters. NFC function can still read actuator parameter even if the actuator is powered off on site.
Electric actuator spec C: The actuator has the self-stroking function.It can automatcially measure the valve stroke.
Electric actuator spec D: The high/low speed can be switched through DIP switch. 500/1000/3000N: high speed 1s/mm, middle speed 2s/mm; 5000N: high speed 2s/mm, middle speed 4s/mm.
Electric actuator spec E: The actuator has the mechanical manual function and manual priority function, that is, when insert the wrench, the actuator will be automatically powered off which is safe and convinent.
Electric actuator spec F: The actuator has local control function which can control the opening and closing of valve by the button on the plate.
Electric actuator spec G: There are LED indicating lights on the actuator cover which is convenient to observe the actuator running status.
Electric actuator spec H: IP54

V port brass ball valve -VBBT_TBL

Nominal diameter DN15-DN50
Media temperature -25~120°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, glycol solution (<50%)
Flange Connection PN16/25
Type of valve 2 ways valve
Threaded connection FF ISO7-1
Flow characteristic A-AB equal-percentage flow characteristic
Rangeability >100:1
Lifetime 100 000 times full open and close
Environment temperature and humidity -15~+55°C, ≤95% RH
Protection level IP54

V port ductile iron ball valve -VBDF_TBF

Nominal diameter DN15-DN50
Media temperature -25~120°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, glycol solution (<50%)
Flange Connection PN16/25
Type of valve 2 ways valve
Threaded connection FF ISO7-1
Flow characteristic A-AB equal-percentage flow characteristic
Rangeability >100:1
Lifetime 100 000 times full open and close
Environment temperature and humidity -15~+55°C, ≤95% RH
Protection level IP54

V port stainless steel ball valve -VBST_TBL

Nominal diameter DN15-DN50
Media temperature -25~120°C
Max allowable pressure 25 bars
Permissible medium Chill and hot water, refrigerant, glycol solution (<50%)
Flange Connection PN16/25
Type of valve 2 ways valve
Threaded connection FF ISO7-1
Flow characteristic A-AB equal-percentage flow characteristic
Rangeability >100:1
Lifetime 100 000 times full open and close
Environment temperature and humidity -15~+55°C, ≤95% RH
Protection level IP54

Balanced float vavle with diaphragm-Bayard J210

Nominal Diameter DN40 to DN250
Media temperature 1°C to 65°C.
Max allowable pressure 10 bars
Permissible medium Clear water, water supply, fire protection, high rise building
Function Control of top water level in reservoirs and storage tanks

Balanced pressure reducing-Bayard F210

Nominal Diameter DN40 to DN200
Media temperature 1°C to 65°C.
Max allowable pressure 25 bars
Permissible medium Clear water, water supply, fire protection, irrigation,drinking water
Flange drilling According to standards EN 1092-2 and ISO 7005-2: ISO PN10, 16 or 25 for DN 50 to 1000 (other drillings on request).
Function Pressure reducing

Hydraulic Control Valves-General-Bayard

Nominal Diameter DN50 to DN1000
Media temperature 1°C to 65°C.
Max allowable pressure 25 bars
Permissible medium Clear water, water supply, fire protection, irrigation, water treatment station,drinking water or 2 mm filtered untraited water.
Flange drilling According to standards EN 1092-2 and ISO 7005-2: ISO PN10, 16 or 25 for DN 50 to 1000 (other drillings on request).
Test of sealing Class A according to standard ISO 5208-2.
Norm of face to face dimension ISO 5752 series 8 (except DN 300).
Body Ductile iron with Fully protected by cataphoresis epoxy coating
Options Pressure reducing, pressure relief, pressure differential, flow limiter, overspeed, altitude valve, float valve,non return valve with slow opening and closing,booster pump protection, pump control valve, surge anticipating valve (anti water hammer valve), on/off electric remote control...

Knife Gate Valve K100

Nominal diameter DN50-DN1200
Media temperature EPDM:-20-120°C
NBR:-20-90°C
Viton:-10 -180°C
PTFE:-196 -200°C
Silicon:-60°C-225°
Metal seat: Depending on body & packing materialC
Pressure Range 10 bars till DN200, above DN consult datasheet
Permissible medium Pulp and paper , water treatment, wasted water, powdery and crystallizing chemical products, wine, cement, pneumatic transportation, storage.
End connection Wafer, lug
Flange connection EN1092-1 PN10/16
ASME B16.5 Class150
ASME B16.47 Class150 Series A
JIS B 2238 10K
BS 10 Table D
Tightness test standard EN 12266-1
DIN3230
ISO5208
MSS SP-81
Tightness test of shell According to EN12266-1 Resistance and tightness of the body : test P11 (1,5 x allowable operating pressure)
Tightness of the seat According to EN12266-2 Test P12 rate A (1,1 x allowable Operating pressure)
ATEX design ATEX 97/9/EC
Ex Il 3 c GID Zone 2 and 22 upon request
Option of body Dutile iron GG25, Stainless steel CF8M

Knife Gate Valve K101-Lug type

Nominal diameter DN50-DN1200
Media temperature EPDM:-20-120°C
NBR:-20-90°C
Viton:-10 -180°C
PTFE:-196 -200°C
Silicon:-60°C-225°
Metal seat: Depending on body & packing materialC
Pressure Range 10 bars till DN200, above DN consult datasheet
Permissible medium Pulp and paper , water treatment, wasted water, powdery and crystallizing chemical products, wine, cement, pneumatic transportation, storage.
End connection Wafer, lug
Flange connection EN1092-1 PN10/16
ASME B16.5 Class150
ASME B16.47 Class150 Series A
JIS B 2238 10K
BS 10 Table D
Tightness test standard EN 12266-1
DIN3230
ISO5208
MSS SP-81
Tightness test of shell According to EN12266-1 Resistance and tightness of the body : test P11 (1,5 x allowable operating pressure)
Tightness of the seat According to EN12266-2 Test P12 rate A (1,1 x allowable Operating pressure)
ATEX design ATEX 97/9/EC
Ex Il 3 c GID Zone 2 and 22 upon request
Option of body Dutile iron GG25, Stainless steel CF8M

Pneumatic actuator

Torques 3-10000NM
Environment temperature -20°C to 160°C
Rotation angle 30 °,45°,60°,90°,120°,180°
Air supply 0.2-1.0 Mpa
Standard VDI/VDE 3845 /NAMUR
Top flange ISO5211
Application Butterfly valve, ball valve

PRV-RM1116-SS304

Nominal diameter DN15-DN50
Media temperature -10°C to 80°C
Pressure Range 16 bars
Permissible medium Hot and cold water, building services, general water supply
Connection Threaded, NPT, BSP, DIN259
Down stream setting range: 0,7 to 4 bar

PRV-RP1001-brass

Nominal diameter DN15-DN50
Media temperature -10°C to 80°C
Pressure Range 16 bars
Permissible medium Hot and cold water, building services, general water supply
Connection Threaded, NPT, BSP, DIN259
Down stream setting range: 0,7 to 4 bar

PRV-RP3095-brass

Nominal diameter DN15-DN100
Media temperature -10°C to 120°C
Pressure Range 25 bars
Permissible medium Water services, heating and air- conditioning plants, compressed air systems
Connection Threaded ISO228 (equivalent to DIN 259 and BS 2779 )
Test Opening/closing test: 10000 times
Body Brass-CW614

Rubber Joint R100

Nominal diameter DN 1/2"-DN3"
Media temperature EPDM:-10°C-95°C
NBR:-10°C-75°C
Pressure Range 16 bars
Permissible medium EPDM:Water distribution, heating and HVAC
NBR: Oil, hydrocarbon, air
Application Absorb vibrations, noises, expension
Connection galvanised ductile iron union nut connections
Rubber EPDM, NBR

Rubber Joint R101

Nominal diameter DN40-600
Media temperature EPDM:-10°C-95°C/NBR:-10°C-75°C
Pressure Range 16 bars till DN300, above 10 bars
Permissible medium EPDM:Water distribution, heating and HVAC /NBR: Oil, hydrocarbon, air
Application Absorb vibrations, noises, expension
Connection galvanised ductile iron union nut connections
Rubber EPDM, NBR